Line 10: Line 10:
 
* fast deployment - disaster recovery scenarios
 
* fast deployment - disaster recovery scenarios
  
= Medical devices =
+
= Medical modalities =
  
 
* ECG
 
* ECG
Line 18: Line 18:
 
** for Parkinson's, to identify uncontrolled shaking and fine-tune dosage -- Code blue
 
** for Parkinson's, to identify uncontrolled shaking and fine-tune dosage -- Code blue
 
** for detecting falls -- UVA
 
** for detecting falls -- UVA
 +
* [http://www.smiths-medical.com/Userfiles/oem/Oxilink_Oxilink%20II.pdf Oxilink OEM Oximeter]
 +
* [http://www.smiths-medical.com/Userfiles/oem/OEM.7127A2.pdf Oximetry board: integrated oximeter/ECG/respiratory board]
 +
* [http://www.smiths-medical.com/bci-oem/ Smith's Medical BCI OEM Technologies]
  
 
= Groups =
 
= Groups =
Line 33: Line 36:
 
'''Companies:'''
 
'''Companies:'''
 
* [http://www.intel.com/healthcare/index.htm?cid=cim:ggl|dighealth_us_digital|k9A2F|s Intel health ]
 
* [http://www.intel.com/healthcare/index.htm?cid=cim:ggl|dighealth_us_digital|k9A2F|s Intel health ]
 +
 +
 +
'''People'''
 +
* [http://www.eng.uah.edu/~jovanov/  Emil Jovanov]
  
 
= Projects =
 
= Projects =
Line 50: Line 57:
 
|[[#AID-N | AID-N]] || Disaster recovery - Triage || Two-tier architecture, 802.15.4 and 802.11 || Motes, PDAs ||SpO2, HR, ECG || Patient monitoring, Continuous monitoring of triage levels
 
|[[#AID-N | AID-N]] || Disaster recovery - Triage || Two-tier architecture, 802.15.4 and 802.11 || Motes, PDAs ||SpO2, HR, ECG || Patient monitoring, Continuous monitoring of triage levels
 
|-
 
|-
| [[#Patient_Centric_Network_Project| Patient Centric Network Project]] || X || X || X ||X || Signal processing algorithms
+
| [[#SMART | SMART]] || disaster recovery, triage || 802.11b || PDAs || SpO2, ECG from MIT || vitals monitoring, analysis & alarms, localization
 +
|-
 +
| [[#Patient_Centric_Network_Project| Patient Centric Network Project]] || || || || || Signal processing algorithms
 
|-
 
|-
 
| [http://www.cs.rochester.edu/~kautz/ac/index.html LACE: Laboratory for Assisted Cognition Environments] || Assisted living || X || X ||X ||  
 
| [http://www.cs.rochester.edu/~kautz/ac/index.html LACE: Laboratory for Assisted Cognition Environments] || Assisted living || X || X ||X ||  
 
|-
 
|-
| Junk|| X || X || X ||X || X
 
 
|}
 
|}
  
Line 71: Line 79:
 
** see [http://www.eecs.harvard.edu/~mdw/papers/codeblue-techrept05.pdf CodeBlue Technical Report]
 
** see [http://www.eecs.harvard.edu/~mdw/papers/codeblue-techrept05.pdf CodeBlue Technical Report]
  
== SMART (Scalable Medeical Alert Response Technology) ==
+
== [http://smart.csail.mit.edu/ SMART] ==
 
+
Scalable Medical Alert Response Technology (SMART)
* Domain: disaster recovery, triage
 
* Network architecture: 802.11b
 
** Two types of devices: patient monitoring and caregiver
 
* Devices: PDAs
 
* Sensors:
 
** medical: [http://www.nonin.com/ SpO2], ECG from MIT
 
* Functions:
 
** vital sign monitoring
 
** vital sign analysis & alarms
 
** localization
 
  
 
'''Notes:'''
 
'''Notes:'''
Line 126: Line 124:
  
  
 +
 +
= Commercial products =
 +
 +
IntelliVue Phillips
 +
 +
- uses 802.11a/e
 +
 +
 +
http://www.medical.philips.com/main/products/patient_monitoring/products/intellivue802_11/index.wpd
 +
http://incenter.medical.philips.com/doclib/enc/fetch/2000/4504/577242/577243/577247/582646/583147/IntelliVue_Telemetry_System_brochure_(Non-US).pdf?nodeid=585849&vernum=4
  
 
= Conferences =
 
= Conferences =

Latest revision as of 00:13, 15 December 2008


Challenges

  • reliability
  • privacy and security
  • power management - not all devices are battery powered
  • diversity - both a challenge and an opportunity
  • fast deployment - disaster recovery scenarios

Medical modalities

Groups


Companies:


People

Projects

Overview

Project Domain Network Architecture Devices Sensors Provides
Code Blue Patient monitoring Flat architecture, just looks at collection Motes SpO2, HR, EKG, motion Patient monitoring, Reliable Routing, Localization
AID-N Disaster recovery - Triage Two-tier architecture, 802.15.4 and 802.11 Motes, PDAs SpO2, HR, ECG Patient monitoring, Continuous monitoring of triage levels
SMART disaster recovery, triage 802.11b PDAs SpO2, ECG from MIT vitals monitoring, analysis & alarms, localization
Patient Centric Network Project Signal processing algorithms
LACE: Laboratory for Assisted Cognition Environments Assisted living X X X

CodeBlue

  • AMDR Routing:
    • support for pub/sub
    • routing state proportional to the # of publishers (an entry in the table for each publisher)
    • route discovery initiated when a device requests to publish data, requires flooding
    • a subscriber that wants to receive data from a channel sends a route reply on the reverse path (handles asymmetric links)
    • routes are updated through periodic floods (every 15s)
    • negative results on mobility
    • path metric (PDR)
      • for each link, estimate LDR by mapping the measured LQI to a link delivery estimator. This model is determined empirically.
      • PDR is the product of all LDRs of the links along the path
    • see CodeBlue Technical Report

SMART

Scalable Medical Alert Response Technology (SMART)

Notes:

Good background section.

References:

  1. Curtis DW, Pino EJ, Bailey JM, Shih EI, Waterman J, Vinterbo SA, Stair TO, Guttag JV, Greenes RA, Ohno-Machado L, SMART An Integrated Wireless System for Monitoring Unattended Patients. J Am Med Inform Assoc 2008 January-February; 15(1):44-53.

AID-N

  • AID-N(Advanced Health and Disaster Network)
  • Uses CodeBlue devices
  • Uses Flows routing (part of Flusk)


References:

  1. Tia Gao; D. Greenspan; M. Welsh; R.R. Juang; A. Alm, "Vital Signs Monitoring and Patient Tracking Over a Wireless Network," Engineering in Medicine and Biology Society, 2005. IEEE-EMBS 2005. 27th Annual International Conference of the , vol., no., pp.102-105, 2005

Alarm-NET

  • Domain: assisted living, circadian activity rhythms (CAR)
  • Network architecture:
    • Spans body networks, sensor networks and IP networks
    • Query service to collect data
    • Emphasis on dynamic security
    • Use CAR information for security and power management
  • Devices: heterogeneous - motes, PDAs and PCs
  • Sensors:
    • medical: pulse, blood oxygenaton
    • non-medical: temperature, light, infrared motion


References:

  1. A. Wood, G. Virone, T. Doan, Q. Cao, L. Selavo, Y. Wu, L. Fang, Z. He, S. Lin, J. Stankovic, “ALARM-NET: Wireless Sensor Networks for Assisted-Living and Residential Monitoring,” Technical Report


WiiSard

WiiSard Trial

Patient Centric Network Project

Commercial products

IntelliVue Phillips

- uses 802.11a/e


http://www.medical.philips.com/main/products/patient_monitoring/products/intellivue802_11/index.wpd http://incenter.medical.philips.com/doclib/enc/fetch/2000/4504/577242/577243/577247/582646/583147/IntelliVue_Telemetry_System_brochure_(Non-US).pdf?nodeid=585849&vernum=4

Conferences

  1. HealthNet 2007

URLs